a

Zero Air Supply

Zero air supply and regular span point check are part of the implemented principle whereas zero and span point check may be carried out automatically on a daily basis.

Explore
a

Particulate Matter

PM10 and PM2.5 are not single components but the mass concentration of all ambient air particles with an aerodynamic diameter smaller than 10 µm (PM10) or 2.5 µm (PM2.5).

Explore
a

Airpointer references

Ambient air quality with regard to health-harming substances also has to be considered on a small scale because local microclimatic conditions may create an air quality.

Explore

We Are A Team Of Industry Experts

A growing number of environmental consultants are using sensor-based methods to gather air quality data on client projects that are budget and time constrained. Supports consultants by providing flexible, integrated monitoring solutions that take the hassle out of monitoring projects – and we uphold best practices for accuracy and traceability so that the resulting reports and recommendations are defensible.

Read more
a

We can generally choose what we want to eat and drink and where we want to be, but not the air we breathe

Logistics video

The airpointer provides reliable measurement data at highly frequented locations. Air quality monitoring at schools, public buildings, shopping malls, and airports (Indoor Air Quality / IAQ).

Mobile operation

It is often necessary to measure briefly at different sites. The compact design of the airpointer makes it the ideal tool for mobile operation. The airpointer ensures flexible air monitoring while using the required reference measurement methods. The airpointer can be quickly transported by car or trailer to the measurement site where it is needed.

Measuring where necessary

People spend more than 80% of their time indoors. Frequently, indoor air quality is not better than outdoors. Therefore, continuous indoor air quality monitoring is essential considering that the health of young or elderly people or people in poor health above all suffers rapidly under poor indoor air conditions.

Permanent installation

Typically mounted on a pole (or a wall if necessary). Permanent installation is necessary when continuous monitoring over an extended period is required. Lifted to the designated position with a crane and mounted with appropriate mounting brackets. It can be relocated within a minimal amount of time.

Calibration

A span gas port in the maintenance door is provided for calibrating the airpointer with external span gas. The user does not have to open the front door thus leaving the temperature inside unaltered.